  • You were right - the previous installer had wrapped the c wire around the others further into the wall on both thermostats.

    I did end up making a frustrating mistake following the directions - at first, since I didn’t find the C wire, I figured I would need the PEK and started following those steps. Ecobee’s steps for the PEK install said that if you have a zoned system [I do] then you’ll have to install it at the zone control and not in the HVAC control board.

    I did that and it blew a very hard to find fuse on the zone board - I ended up having to order online after not finding it at the various supply stores locally. When I called ecobee they said that the PEK should never be installed in the zone board itself - which is the opposite of what the app told me to do.

    Anyway, once I found the C wire I realized I didn’t need the PEK after all. I replaced the fuse after a few chilly nights and both zones are up and running now.